Himoinsa silenced diesel generators, 8 to 1,200 kVA

8 to 1,200 kVA

Stocked in Toowoomba

Continuous-rated kVA

Single & three phase

Yanmar, IVECO and Scania diesel

~35 dB(A) silenced

Himoinsa is a Yanmar company and one of the world’s major generator manufacturers. The range runs on Yanmar, IVECO and Scania diesel engines depending on size, housed in a sound-attenuated steel enclosure that cuts roughly 35 dB(A), so the set can run near stock, sheds, staff or neighbours without the racket of an open genset. Every unit is diesel, water-cooled, with electronic voltage regulation for clean, stable three-phase or single-phase power.

We stock selected sizes in Toowoomba and supply generators up to 1,200 kVA on order (ex Brisbane or Sydney), specified to your load. The range is grouped below by the job it does. Every model comes with a spec sheet, so you can self-identify, then call to confirm stock and price. A note on the numbers: the kVA figures listed are continuous (prime) power, rated for 24/7 running. Standby output is around 10% higher, so if you are sizing for occasional backup rather than constant load, there is a little more headroom than the continuous figure suggests.

Single-Phase Backup — 9 to 30kVA · 240V

For sheds, workshops, single-phase pumps and property backup

The Himoinsa HYW M5 single-phase range, for properties and operations on standard single-phase supply. Silenced, diesel, and built to run long hours without fuss.

Three-Phase, Small to Mid — 8 to 160kVA · 415V

For irrigation, pump sets, workshops and three-phase site power. Selected sizes are stocked in Toowoomba.

The HYW T5 three-phase range, across this band, is the workhorse for irrigation, pumps and general three-phase supply. This is where most of our stocked generators sit, so if you need three-phase power quickly, start here.

Large Three-Phase & Prime Power — 200 to 600 kVA · 415V

For feedlots, cotton gins, processing plants, and prime or standby power for a whole operation

The larger generator range runs on Yanmar, IVECO and Scania diesel engines depending on size, for continuous, heavy-load running. These are the units that carry a feedlot through a grid outage or run a site off-grid for weeks. Supplied to order and specified to your load, whether that is standby for emergencies or prime power as the main source.

HYW-13 M5

Himoinsa

HYW-13 M5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
9.3 kVA
Phase
1-phase
Engine model
Yanmar 3TNV88BGGEH (3-cyl, 1.64L, natural)
HYW-13 M5

Himoinsa

HYW-13 M5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
9.3 kVA
Standby output
10 kVA
Phase
1-phase
Engine model
Yanmar 3TNV88BGGEH (3-cyl, 1.64L, natural)
Alternator
Stamford
Amperage
43 A
HYW-20 M5

Himoinsa

HYW-20 M5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
15.7 kVA
Phase
1-phase
Engine model
Yanmar 4TNV84TBGGEH (4-cyl, 2.0L, turbo)
HYW-20 M5

Himoinsa

HYW-20 M5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
15.7 kVA
Standby output
17.2 kVA
Phase
1-phase
Engine model
Yanmar 4TNV84TBGGEH (4-cyl, 2.0L, turbo)
Alternator
Stamford
Amperage
71 A
Sound level @ 7m
57 dB(A)
HYW-30 M5

Himoinsa

HYW-30 M5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
26.4 kVA
Phase
1-phase
Engine model
Yanmar 4TNV98GGEH (4-cyl, 3.3L, natural)
HYW-30 M5

Himoinsa

HYW-30 M5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
26.4 kVA
Standby output
29 kVA
Phase
1-phase
Engine model
Yanmar 4TNV98GGEH (4-cyl, 3.3L, natural)
Alternator
Stamford
Amperage
114 A
HYW-40 M5

Himoinsa

HYW-40 M5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
30.4 kVA
Phase
1-phase
Engine model
Yanmar 4TNV98TGGEH (4-cyl, 3.3L, turbo)
HYW-40 M5

Himoinsa

HYW-40 M5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
30.4 kVA
Standby output
35 kVA
Phase
1-phase
Engine model
Yanmar 4TNV98TGGEH (4-cyl, 3.3L, turbo)
Alternator
Stamford
Amperage
~130 A

HYW-8 T5

Himoinsa

HYW-8 T5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
8.3 kVA
Phase
3-phase
Engine model
Yanmar 3TNV76GGEH (3-cyl, 1.1L, natural)
HYW-8 T5

Himoinsa

HYW-8 T5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
8.3 kVA
Standby output
9.6 kVA
Phase
3-phase
Engine model
Yanmar 3TNV76GGEH (3-cyl, 1.1L, natural)
Alternator
Mecc Alte
HYW-13 T5

Himoinsa

HYW-13 T5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
12.5 kVA
Phase
3-phase
Engine model
Yanmar 3TNV88BGGEH (3-cyl, 1.64L, natural)
HYW-13 T5

Himoinsa

HYW-13 T5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
12.5 kVA
Standby output
13.7 kVA
Phase
3-phase
Engine model
Yanmar 3TNV88BGGEH (3-cyl, 1.64L, natural)
Alternator
Mecc Alte
Fuel tank
22 standard; 40 or 100 optional
RuntimeAt 75% load unless the value says otherwise.
9 h on 22L tank (2.5 L/h at 75%); ~40 h on 100L
Sound level @ 7m
62 ±2.4 dB(A)
Enclosure
Soundproof steel canopy, rock-wool lined, residential silencer -35dB(A)
Dimensions (L×W×H)
1480 x 750 x 1100 (standard 22L tank; 1485 x 750 x 1285 with 100L tank)
Dry weight
506 wet (22L version) / 621 wet (100L version)
HYW-17 T5

Himoinsa

HYW-17 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
17.1 kVA
Phase
3-phase
Engine model
Yanmar 4TNV88BGGEH (4-cyl, 2.2L, natural)
HYW-17 T5

Himoinsa

HYW-17 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
17.1 kVA
Standby output
18.4 kVA
Phase
3-phase
Engine model
Yanmar 4TNV88BGGEH (4-cyl, 2.2L, natural)
Alternator
Stamford 17.2/18.4 or Mecc Alte 17.5/19.2
HYW-20 T5

Himoinsa

HYW-20 T5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
20 kVA
Phase
3-phase
Engine model
Yanmar 4TNV84TBGGEH (4-cyl, 2.0L, turbo)
HYW-20 T5

Himoinsa

HYW-20 T5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
20 kVA
Standby output
22 kVA
Phase
3-phase
Engine model
Yanmar 4TNV84TBGGEH (4-cyl, 2.0L, turbo)
Alternator
Mecc Alte
HYW-35 T5

Himoinsa

HYW-35 T5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
34 kVA
Phase
3-phase
Engine model
Yanmar 4TNV98GGEH (4-cyl, 3.3L, natural)
HYW-35 T5

Himoinsa

HYW-35 T5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
34 kVA
Standby output
37 kVA
Phase
3-phase
Engine model
Yanmar 4TNV98GGEH (4-cyl, 3.3L, natural)
Alternator
Mecc Alte
HYW-45 T5

Himoinsa

HYW-45 T5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
41 kVA
Phase
3-phase
Engine model
Yanmar 4TNV98
HYW-45 T5

Himoinsa

HYW-45 T5

Stocked in Toowoomba

Output (prime)Continuous power. Standby is roughly 10% higher.
41 kVA
Standby output
45 kVA
Phase
3-phase
Engine model
Yanmar 4TNV98
Alternator
Mecc Alte
HYW-60 T5

Himoinsa

HYW-60 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
60 kVA
Phase
3-phase
Engine model
Yanmar 4TNV106T-GGE (4-cyl, 4.4L, turbo)
HYW-60 T5

Himoinsa

HYW-60 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
60 kVA
Standby output
66 kVA
Phase
3-phase
Engine model
Yanmar 4TNV106T-GGE (4-cyl, 4.4L, turbo)
Alternator
Mecc Alte
HYW-75 T5

Himoinsa

HYW-75 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
75 kVA
Phase
3-phase
Engine model
Yanmar 4F104SM2A.GL (4-cyl, 4.5L, turbo)
HYW-75 T5

Himoinsa

HYW-75 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
75 kVA
Standby output
83 kVA
Phase
3-phase
Engine model
Yanmar 4F104SM2A.GL (4-cyl, 4.5L, turbo)
Alternator
Mecc Alte
HYW-100 T5

Himoinsa

HYW-100 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
100 kVA
Phase
3-phase
Engine model
Yanmar 4F104TM2A.GL (4-cyl, 4.5L, turbo)
HYW-100 T5

Himoinsa

HYW-100 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
100 kVA
Standby output
110 kVA
Phase
3-phase
Engine model
Yanmar 4F104TM2A.GL (4-cyl, 4.5L, turbo)
Alternator
Mecc Alte
HYW-125 T5

Himoinsa

HYW-125 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
125 kVA
Phase
3-phase
Engine model
Yanmar 4F104TM3.GL (4-cyl, 4.5L, turbo)
HYW-125 T5

Himoinsa

HYW-125 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
125 kVA
Standby output
136 kVA
Phase
3-phase
Engine model
Yanmar 4F104TM3.GL (4-cyl, 4.5L, turbo)
Alternator
Mecc Alte
HYW-160 T5

Himoinsa

HYW-160 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
160 kVA
Phase
3-phase
Engine model
Yanmar 6F104TM3A.GL (6-cyl, 6.7L, turbo aftercooled)
HYW-160 T5

Himoinsa

HYW-160 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
160 kVA
Standby output
175 kVA
Phase
3-phase
Engine model
Yanmar 6F104TM3A.GL (6-cyl, 6.7L, turbo aftercooled)
Alternator
Mecc Alte
Sound level @ 7m
68 dB(A)

HYW-200 T5

Himoinsa

HYW-200 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
200 kVA
Phase
3-phase
Engine model
Yanmar 6F104TM7.GL (6-cyl, 6.7L, turbo)
HYW-200 T5

Himoinsa

HYW-200 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
200 kVA
Standby output
220 kVA
Phase
3-phase
Engine model
Yanmar 6F104TM7.GL (6-cyl, 6.7L, turbo)
Alternator
Mecc Alte
HYW-245 T5

Himoinsa

HYW-245 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
250 kVA
Phase
3-phase
Engine model
Yanmar 6F104TE8W.GL (6-cyl, 6.7L, turbo)
HYW-245 T5

Himoinsa

HYW-245 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
250 kVA
Standby output
275 kVA
Phase
3-phase
Engine model
Yanmar 6F104TE8W.GL (6-cyl, 6.7L, turbo)
Alternator
Mecc Alte
HYW-310 T5

Himoinsa

HYW-310 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
300 kVA
Phase
3-phase
Engine model
Yanmar 6F117TE4.GL (6-cyl, 8.7L, turbo)
HYW-310 T5

Himoinsa

HYW-310 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
300 kVA
Standby output
330 kVA
Phase
3-phase
Engine model
Yanmar 6F117TE4.GL (6-cyl, 8.7L, turbo)
Alternator
Mecc Alte
HYW-350 T5

Himoinsa

HYW-350 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
350 kVA
Phase
3-phase
Engine model
Yanmar 6F135TE3A.GL (6-cyl, 12.9L, turbo)
HYW-350 T5

Himoinsa

HYW-350 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
350 kVA
Standby output
370 kVA
Phase
3-phase
Engine model
Yanmar 6F135TE3A.GL (6-cyl, 12.9L, turbo)
Alternator
Mecc Alte
HYW-400 T5

Himoinsa

HYW-400 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
400 kVA
Phase
3-phase
Engine model
Yanmar 6F135TE3A.GL (6-cyl, 12.9L, turbo)
HYW-400 T5

Himoinsa

HYW-400 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
400 kVA
Standby output
440 kVA
Phase
3-phase
Engine model
Yanmar 6F135TE3A.GL (6-cyl, 12.9L, turbo)
Alternator
Mecc Alte
HYW-500 T5

Himoinsa

HYW-500 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
500 kVA
Phase
3-phase
Engine model
Yanmar 6F135TE7.GL (6-cyl, 12.9L, turbo)
HYW-500 T5

Himoinsa

HYW-500 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
500 kVA
Standby output
541 kVA
Phase
3-phase
Engine model
Yanmar 6F135TE7.GL (6-cyl, 12.9L, turbo)
Alternator
Mecc Alte
HSW-500 T5

Himoinsa

HSW-500 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
505 kVA
Phase
3-phase
Engine model
Scania DC13-72A (6-cyl, 12.7L, turbo)
HSW-500 T5

Himoinsa

HSW-500 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
505 kVA
Standby output
552 kVA
Phase
3-phase
Engine model
Scania DC13-72A (6-cyl, 12.7L, turbo)
Alternator
Stamford
HYW-600 T5

Himoinsa

HYW-600 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
598 kVA
Phase
3-phase
Engine model
Yanmar 6F141TE1W.GL (6-cyl, 15.9L, turbo)
HYW-600 T5

Himoinsa

HYW-600 T5

To order

Output (prime)Continuous power. Standby is roughly 10% higher.
598 kVA
Standby output
656 kVA
Phase
3-phase
Engine model
Yanmar 6F141TE1W.GL (6-cyl, 15.9L, turbo)
Alternator
Mecc Alte

Outputs are continuous (prime) power. Standby is roughly 10% higher. Larger units available on request: we supply generators up to 1,200 kVA, or can specify multiple sets in parallel.

Not sure which size you need? Tell us the load and we’ll spec it.

A rough guide to generator sizing

The most expensive generator is the one that is too small for the job. Undersize it and it runs flat out, overheats, and suffers premature failure. The right size is not just the kVA on the nameplate, it is your total running load plus the starting surge of any electric motors, which can pull six to eight times their running current at start-up without motor automation and control. This is a rough starting point — the real number comes from a two-minute conversation about what you are actually running.

Rough sizeTypically suits
8 to 20kVASheds, workshops, single pumps, three-phase tools, property backup
20 to 45kVAIrrigation pumps, dairies, small processing plants, multiple motors on a site
50 to 150kVAFeedlots, cotton gins, irrigation, workshops with heavy plant
150 to 1,200 kVAPrime power for whole operations, feedlots, transport depots, processing plants, large commercial businesses, off-grid sites
Himoinsa Silenced Diesel Generator Running as Standby Power Beside a Lit Cold Store and Cattle Yards at Dusk
Himoinsa Silenced Diesel Generator Supplying Temporary Power on a South East Queensland Shed Build

Where our generators are working

These are real installations across Queensland and northern New South Wales. Different sizes, different jobs, same brief: keep the power on where an outage costs real money.

Himoinsa lighting towers

For harvest, night works, feedlots, construction sites and events, we also supply Himoinsa LED lighting towers: the compact trailer-mounted Apolo and the H-Box+ box unit, each running four 350W LED heads off an efficient Yanmar set. Same brand, same reliability, built to light a work area through the night.

Spec sheets: Apolo Compact (PDF)   H-Box+ M5 (PDF)

Himoinsa Apolo Compact LED Lighting Tower Lighting a Night Grain Harvest on the Darling Downs
Model Lamp configuration Stock
Apolo Compact (trailer) 4 x 350W LED Stocked in Toowoomba
H-Box+ M5 (box) 4 x 350W LED To order

The generator is the easy part

Technician Servicing a White Himoinsa Silenced Diesel Generator in a Workshop

Sized to your load, not a catalogue

We spec the unit around what you actually run, including motor starting loads, so it fits the first time and does not run itself into the ground.

Stocked and ready in Toowoomba

The sizes the region buys most are on the shelf. When you need three-phase power quickly, the odds are it is already here.

After-hours emergency supply

Power does not fail at convenient times. After-hours emergency supply is available on 0455 786 760, because a feedlot with stock to water cannot wait until Monday.

Backed by our own workshop

We supply it and we service it, from our own workshop with our own technicians. The relationship does not end when the generator leaves the yard.

Generator questions, answered straight

It comes down to your total running load plus the starting surge of any motors, and whether the generator is backup or prime power. Electric motors draw several times their running current at start-up, so a generator sized only to the running total will struggle. Tell us what you need to run, or the equipment list, and we’ll size it properly rather than leaving you to guess. The sizing guide above is a rough starting point.

Standby means the generator sits ready and takes over when the grid fails, running occasionally. Prime power means the generator is the main source, running continuously where there is no mains or it is unreliable. They are sized and built differently, a prime-power unit is made to run hard for long hours, so it matters which you actually need. One thing worth knowing when you compare figures: the kVA ratings we list are continuous (prime) power, rated for constant running. Standby output is around 10% higher, so a unit has a little more capacity for occasional-use backup than its continuous figure suggests. We’ll match the unit to the duty.

Yes. Most of our stocked range is three-phase (415V) diesel, from 8kVA up, which is what irrigation, pumps, processing and most industrial sites run on. We also carry single-phase (240V) units for smaller and property-backup jobs. Tell us your supply and load and we’ll point you to the right one.

A silenced (or soundproof) generator is housed in a sound-attenuated steel enclosure that cuts noise by around 35 dB(A) versus an open set. That lets it run near stock, staff, sheds or neighbours without the noise being a problem. For most site, feedlot and standby installations, silenced is the standard choice.

Yes, but the generator has to be sized for the motor’s starting current, not just its running load, because a motor can draw six to eight times its running current at start-up without motor automation and control. Getting this wrong is the most common sizing mistake. We factor motor starting loads into every sizing, which is exactly the sort of thing an online seller shipping a box cannot do for you.

Yes. For standby installations we pair the generator with an automatic transfer switch so it starts and takes the load on its own when the grid drops, then hands back when mains returns, with no one needing to be on site. For anything you cannot afford to have go dark, it is worth doing.

We supply across Toowoomba, the Darling Downs and out into regional Queensland, and back what we sell with our own service department and an after-hours line for emergencies. A regional supplier who can actually get to you beats a box shipped from interstate when something needs attention.

It depends on size, phase, and whether you need standby or prime-power configuration and automatic changeover, so anything from a few thousand for a small single-phase unit up into the tens of thousands for a large three-phase set. Tell us the size and application and we’ll give you a real figure. We size it right first, so you are not paying for capacity you do not need.

Make sure you’re on the right page

This page covers the silenced diesel range for fixed installations and serious three-phase power: feedlots, irrigation, standby and prime power. If instead you need something you can throw on the ute, move between job sites, or run a smaller single-phase job, that is our portable range, Powerlite and TecnoGen, and it lives on its own page.